Configuration, Startup, and Operation of Recorder with Display

4.3.6 Configuration Procedure

Introduction

The configuration prompts are sequenced in a group/function hierarchy as shown in Figure 4-2.Once you have set the input switches in SW6 as described in Subsection 4.3.5, configure all the function parameters that are applicable for your recorder model and application. During configuration some function parameters will not be displayed if they do not apply to your application. For example, if you set the control group function “CONTRL” to “DIS”, disabling control, then no other control group prompts will be displayed.

To enter your selections or values, follow the procedure in Table 4-4and fill in the values or selections on the worksheet in Subsection 4.3.21. Keep this worksheet as a record of how your recorder was configured.

This procedure tells you the keys to press to get to any set up group (and any associated function parameters prompt).

Procedure

Follow the procedure listed in Table 4-4to access the set up groups and function prompts. If you have a 2-pen recorder, be sure to identify individual parameters for each pen and control loop as applicable.

Make sure lock set up group “LOCK” function is set to “NONE” or “CAL.” See Subsection 4.3.19.

Table 4-4 Configuration Procedure

Step

Operation

Press

Result

1

Select Set Up mode

 

 

Upper Display

 

 

 

SET

 

 

 

 

 

 

SET

Lets you know you are in the

 

 

UP

 

 

 

 

 

 

 

 

 

 

configuration mode and a set up group

 

 

 

 

 

 

 

 

 

 

title is being displayed in the lower

 

 

 

 

Lower Display

display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

This is the first set up group title.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Select any set up group

 

• Successive presses of the

 

key will display

SET

SET UP

 

 

 

the other set up group titles shown in the prompt

 

 

UP

 

 

 

 

 

hierarchy in Figure 4-2.

 

 

 

 

 

 

 

• You can also use the [▲] [▼] keys to scan the set up

 

 

 

 

groups in both directions.

 

 

 

• Stop at the set up group title which describes the

 

 

 

 

group of parameters you want to configure. Then

 

 

 

 

proceed to the next step.

3

Select a function parameter

 

 

Upper Display

 

 

 

 

 

 

 

 

 

 

FUNC

 

xxxx

Shows the current value or selection for

 

 

 

 

 

 

 

 

 

the first function prompt of the set up

 

 

 

 

 

 

 

 

 

 

group that you have selected.

 

 

 

 

Lower Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DECMAL

Shows the first function prompt within

 

 

 

 

 

 

 

 

 

 

the selected set up group.

 

 

 

Example displays show Input group function prompt

 

 

 

“DECMAL” and the value selected.

12/03

DR4300 Circular Chart Recorder Product Manual

83

Page 95
Image 95
Honeywell DR4300 manual Configuration Procedure, Step Operation Press Result