Honeywell DR4300 manual Diagnostic Error Messages

Models: DR4300

1 262
Download 262 pages 56.21 Kb
Page 143
Image 143

Configuration, Startup, and Operation of Recorder with Display

4.5.1.4 Diagnostic Error Messages

Recorders with displays run background tests as described in Section 8 – Troubleshooting and Pen Alignment of Recorders with Display to verify data and memory integrity. If there is a malfunction, an error message will blink in the lower display. If more than one self-diagnostic test fails, the display will cycle through the appropriate error messages.

A list of background test error messages is in Table 4-28.

If any of these error messages are displayed, refer to Section 8 for information on correcting the problem.

In addition, an error message will be displayed if the operator tries to run a setpoint program in which the number of the ending segment is lower than the segment number of the start segment. See Appendix C for details.

 

Table 4-28 Error Messages

Prompt

Description

 

 

CALERR

Indicates failure of the calibration test.

 

 

CFGERR

Indicates failure of the configuration test.

 

 

EEFAIL

Unable to write to nonvolatile memory

 

 

FAILSF

Failsafe value being used as output

 

 

INP FL

Two consecutive failures of input integration

 

 

INPRNG

Input out-of-range

 

 

P1 ERR or

Indicates error on channel other than the one on display.

P2 ERR

 

 

 

RAMTST

Indicates failure of the RAM test.

 

 

SEGERR

Indicates that the number of the setpoint program’s end segment is lower

 

than the segment number of the start segment.

 

 

ATTENTION

In addition to error messages, the recorder will display special status messages when optional features are active.

If the lower display flashes “TUNING”, the recorder is in the process of automatically determining tuning parameters using the Accutune II feature described in Appendix D.

If the lower display flashes “RUN n” or “HOLD”, the recorder is executing setpoint program “n” as described in Appendix C, and the run or hold action was initiated locally.

If the lower display flashes “run n” or “hold”, the recorder is executing setpoint program “n”, and the run or hold action was initiated remotely.

12/03

DR4300 Circular Chart Recorder Product Manual

131

Page 143
Image 143
Honeywell DR4300 manual Diagnostic Error Messages