PHY Functionality and Features

11.6.1False Link

When the PHY is first powered on, reset, or encounters a link down state, it must determine the line speed and operating conditions to use for the network link.

The PHY first checks the MDIO registers (initialized via the Hardware Control Interface or written by software) for operating instructions. Using these mechanisms, programmers can command the PHY to do one of the following:

Force twisted-pair link operation to:

1000T Full Duplex

1000T Half Duplex

100TX, Full Duplex

100TX, Half Duplex

10BASE-T, Full Duplex

10BASET, Half Duplex

Allow Auto-Negotiation/parallel-detection.

In the first six cases (forced operation), the PHY immediately begins operating the network interface as commanded. In the last case, the PHY begins the Auto-Negotiation/parallel-detection process.

11.6.2Forced Operation

Forced operation can be used to establish 10 and 100 links, and 1000 links for test purposes. In this method, Auto-Negotiation is disabled completely and the link state of the PHY is determined by PHY register 0d.

Note: When speed is forced, the MDI/MDI-X crossover feature is not functional.

In forced operation, the programmer sets the link speed (10, 100, or 1000) and duplex state (full or half). For Gigabit (1000) links, the programmer must explicitly designate one side as the Master and the other as the Slave. Table 10-1summarizes link establishment procedures.

Table 10-1. Determining Duplex State Via Parallel Detection

Configuration

Result

 

 

Both sides set for Auto-Negotiate.

Link is established via Auto-Negotiation.

 

 

Both sides set for forced operation.

No problem as long as duplex settings match.

 

 

One side set for Auto-Negotiation and the other for

Link is established via parallel detect.

forced, half-duplex.

 

 

 

One side set for Auto-Negotiation and the other for

Link is established; however, sides disagree, resulting

in transmission problems. Forced side is full-duplex,

forced full-duplex.

Auto-Negotiation side is half-duplex.

 

 

 

Software Developer’s Manual

191

Page 205
Image 205
Intel PCI-X manual False Link, Forced Operation, Determining Duplex State Via Parallel Detection, Configuration Result