1010 NTCK16 Generic Central Office Trunkcards
LD 16 - Route Data Block for NTCK16AX.
Prompt Response Description
REQ: NEW Define a new unit
TYPE: COT Define a new Route Data Block
CUST xx Customer number as defined in LD 15.
ROUT Route number
0-511 Range for Large System, Call Server 1000E, and
Media Gateway 1000E
0-127 Range for Small System, CS 1000E system,
Media Gateway 1000B, and
Media Gateway 1000T
TKTP COT Define trunk type as Central Office
ICOG IAO Incoming and Outgoing trunk
CNTL YES Changea trunk timer
TIMER RGV256 Set Ring Validation Timer to 128 ms.
MR (NO) PPM XLD PPM is off, buffered, or unbuffered on this route.
Trunk Data Block

Respond to the prompts in LD 14 as shown:

LD 14 - TrunkData Block for NTCK16AX.
Prompt Response Description
REQ: NEW Define a new trunk unit
TYPE: COT Central Office Trunk
TN Terminal Number
l s c u Format for Large System, Call Server
1000E, and Media Gateway 1000E,
where l = loop, s = shelf, c = card, u
= unit
XTRK
(See note on page 803.) XCOT Type is IPE COT
CDEN (8D) Card density is 8D (default)
SIGL LOP Loop start signaling
PPID
(See page 803.) Xx 04 Ireland/Turkey 12 KHz
03 Turkey 16 KHz
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.