352 NT5D97 Dual-port DTI2 PRI2 card
Reference clock errors
CS 1000 software checks at intervals of 1 to 15 minutesto see if a clock
controller or reference-clock error has occurred. (The interval of this check
can be configured in LD 73).
In tracking mode, at anyone time, there is one active clock controller which
is tracking on one referenceclock. If a clock controller error is detected, the
system switches to the back-up clock controller, without affectingwhich
reference clock is being tracked.
A reference-clockerror occurs when there is a problem with the clock driver
or with the reference clock at the far end. If the clock controller detects a
reference-clock error,the reference clocks are switched.
Automatic clock recovery
A command for automatic clock recovery can be selected in LD 60 with
the command EREF.
A DDP2 loop is disabled when it enters a local-alarm condition. If the local
alarm is cleared, the loop is enabled automatically. When the loop is
enabled, clock tracking is restored in the followingconditions:
If the loop is assigned as the primary reference clock but the clock
controller is tracking on the secondary reference or in free-run mode, it
is restored to tracking on primary.
If the loop is assigned as the secondary reference clock but the clock
controller is in free-run mode, it is restored to tracking on secondary.
If the clock check indicates the switch is in free-run mode:
Trackingis restored to the primar y referenceclock if defined.
If the primary reference is disabled or in local alarm, tracking is
restored to the secondary reference clock if defined.
Note: If the system is put into free-run mode by the craftsperson,
it resumes tracking on a reference clock unless the clock-switching
option is disabled (LD 60, command MREF), or the reference clock
is "undefined" in the database.
Automatic clock switching
If the EREF command is selected in LD 60, tracking on the primary or
secondary reference clock is automatically switched in the followingmanner :
If software is unable to track on the assigned primary reference clock, it
switches to the secondary reference clock and sends appropriate DTC
maintenance messages.
If software is unable to track on the assigned secondary reference clock,
it switches to free run.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008