903
NTAK20 Clock Controllerdaughterboard
Contents This section contains information on the following topics:
"Introduction" (page 903)
"Physical description" (page 909)
"Functional description" (page 910)
IntroductionDigital trunking requires synchronized clocking so that a shift in one
clock source results in an equivalent shift in all parts of the network.
Synchronization is accomplished with an NTAK20 clockcontroller
daughterboard in each Media Gateway that contains a digital trunk card.
The NTAK20clock controller daughterboard mounts directly on the following
cards:
NTAK091.5Mb DTI/PRI
NTBK50 2.0 Mb PRI
NTRB21 DTI/PRI/DCH TMDI
NTBK22 MISP
NT6D70 SILC
NT6D71 UILC
Note: The card is restricted to slots 1 through 3 in EMC- type cabinets
(such as NAK11Dx and NTAK11Fxcabinets). It does not work in slots 4
through 10 in these cabinets.
The NTAK20clock controller card supports 1.5 Mb, 2.0 Mb, and 2.56 Mb
clock recovery rates.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.