Applications 797
The TRC and NTC COS options determine the operation of the switchable
pads contained in the trunk circuits. They are assigned as follows:
TRC for a two-wire non-VNL trunk facilitywith a loss of greater than 2
dB or for which impedance compensation is provided,or for a four-wire
non-VNL facility.
NTC for a two-wirenon-VNL trunk facility with a loss ofless than 2 dB or
when impedance compensation is not provided.
In Option 11C systems, Table310 "Insertion Loss from IPE Ports to IPE
Ports (measured in dB)" (page 797) shows the insertion loss from IPE port
to IPE port.
Table310
Insertion Loss from IPE Ports to IPE Ports(measured in dB)
Paging trunk operation
When used in the paging mode, a trunk is connected to a customer-provided
paging amplifier system (not zone selectable). When the trunk is accessed
by dial-up or attendant-key operation, it provides aloop closure across
Nortel Communication Server 1000