Functional description 345
Table150 "NTBK51AA daughterboard address select switch settings" (page
345) shows the possible selection of the NTBK51AA D-channel.
Table150
NTBK51AA daughterboard address select switch settings
Device Address Switch Setting
0OFF OFF OFF OFF
1ON OFF OFF OFF
2OFF ON OFF OFF
3ON ON OFF OFF
4OFF OFF ON OFF
5ON OFF ON OFF
6OFF ON ON OFF
7ON ON ON OFF
8OFF OFF OFF ON
9ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
Note 1: The system contains a maximum number of 16 DCHI, MSDL, and DDCH devices. The
Device Addresses are equivalent to the MSDL DNUM designations.
Note 2: Device address 0 is commonly assigned to the System TTYD Monitor.
NT5D97AD DIP switch settings
The the NT5D97 DDP2 card is equipped with 6x2 sets of DIP switches for
trunk parameters settings for port0 and port1 respectively. Additionally,
the DDP2 card is equipped with one set of four DIP switches forthe Ring
Ground setting. The NT5D97AA/AB has one set of eight DIP switches and
NT5D97AD has two sets of ten DIP switches forthe D-channel Handler
parameters setting.
The DIP switches are used for the setting of default values of certain
parameters. Firmware reads the general purpose switches, which sets the
default values accordingly.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23May 2008