198 NT5D11 and NT5D14 Lineside T1 Interface cards
XPEC
Address S1 Switch
Position 3 S1 Switch
Position 4 S1 Switch
Position 5 S1 Switch
Position 6
07 Off On On On
08 On Off Off Off
09 On Off Off On
10 On Off On Off
11 On Off On On
12 On On Off Off
13 On On Off On
14 On On On Off
15 On On On On
Tabl e 93
Lineside T1 card - T1 Switch 2 (S2) dip switch settings
Dip Switch
Number Characteristic Selection
1T1 framing On = D4
Off = ESF
2T1 Coding On = AMI
Off = B8ZS
3–5 CPE or CSU distance See Table 94 "Lineside T1 card -
CPE or CSU distance dip switch
settings (Switch S2, positions 3
- 5)" (page 198)
6Line processing on T1 link failure On = On-hook
Off = Off-hook
7Daisy-chaining to MMI On = Yes
Off = No
8MMI Master or Slave On = Master
Off = Slave
Tabl e 94
Lineside T1 card - CPE or CSU distance dip switch settings (Switch S2, positions 3 - 5)
Distance S2 Switch
Position 3 S2 Switch
Position 4 S2 Switch
Position 5
0–133 On Off Off
134–266 Off On On
267–399 Off On Off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.