416 NT6D80 MSDL card
Cause: The MSDL card is not installed or is unable to respond to the
messages from the system.
Action:
Check the MSDL messages on the console and take the action
recommended. Refer to Software Input/Output Reference —
Administration (NN43001-611).
Verify that the address switches on the MSDL are set correctly.
Verify that the card is properly installed in the shelf for at least 5 minutes.
If the problem persists, manually disable the cardby entering the DIS
MSDL x. Follow the steps described in "Previously operating MSDL
cards" (page 413).
SYSTEM DISABLED—SELF-TESTING
Cause: The MSDL card has reset itself or the system has reset the card to
perform self-tests. Self-tests are in progress.
Action:
Wait until self-tests are completed. Under some circumstances, the
self-tests may take up to 6 minutes to complete.
Take the action described in the appropriate section below
("SYSTEM DISABLED—SELF-TESTS PASSED" or "SYSTEM
DISABLED—SELF-TESTS FAILED").
SYSTEM DISABLED—SELF-TESTS PASSED
Cause: The MSDL card passed self-tests. The system automatically
downloads the MSDL base code, if needed, and attempts to enable the
card using autorecovery. If a diagnostic program (overlay) is active, the
downloading of the MSDL base code occurs later.
Action:
Wait to see if the system enables the card immediately. If the
MSDL is enabled, no further action is necessary.
If the MSDL base code download fails five times, autorecovery
stops. The following appears in response to the STAT MSDL x
command;
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.