Configuration 785
Each of the four trunk circuits on the E and M trunk card can be individually
configured for trunk type, companding mode, and port-to-port loss
compensation. Configuring the card requires both jumper changes and
configuration software service entries.
The locations of the jumpers are shown in Figure 255 "E and M Trunkcard -
jumper locations" (page 786).
Each of the four trunk circuits on the E and M trunk card can be individually
configured for trunk type, companding mode, and port-to-port loss
compensation. Configuring the card requires both jumper changes and
configuration software service entries.
Jumper settings
The NT8D15 E and M Trunkcard serves various transmission requirements.
The four units on the card can operate in A-Law or µ-Lawcompanding
modes, which are selected by service change entries. Each unit can be
independently configured for 2-wire E and M, 4-wire E and M, and paging
trunk types. The trunk type is selected by service change entries and
jumper strap settings.
See Table303 "E and M Trunk card - jumper strap settings" (page 787).