Functional description 731
Four-wire E and M signaling type I and II, two-waydial repeating (ESN
and Non-ESN)
echo suppression for type I
Switchable seven dB and 16 dB for carrier interface for ESN
applications
Transmitand receive of voice through two separate paths
TypeI signaling through E and M leads
TypeII signaling
Near-end seizure with MA/MB leads
Far-end detection with EA/EB leads
Paging trunk loop OAID operation
Support access by low resistance path at the PA/PBlead.
All call zone paging is not supported.
Twoto four-wire conversion of the transmission path
Trunk unit functions
The functions provided by each unit on the E and M Trunkcard include
2-wire signaling, 4-wire signaling, and paging operation as follows:
2-wire, E and M TypeI signaling (see Figure 228 "E and M TypeI
signaling" (page 732)) with:
near-end seizure and outpulsing with M lead
ground detection with E lead
voice transmission through tip and ring for transmit and receive
4-wire, E and M TypeI and II signaling (see Figure 229 "E and M Type II
signaling" (page 732)), 2-way dial repeating with:
echo suppression for TypeI signaling
switchable 7 dB and 16 dB pads for carrier interface
voice transmission and reception through two separate paths
TypeI signaling through E and M leads
TypeII signaling with near-end seizure by SB/M leads and far-end
detection by E/SG lead
4-wire, DX signaling (see Figure 230 "4-wire DX signaling" (page 734))
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.