412 NT6D80 MSDL card
Enabling the MSDL
Enter ENL MSDL x to enable the MSDL manually. If the MSDL base code
has not been previously downloaded or if the card version is different from
the one on the system disk, the software is downloaded and the card is
enabled.
Toforce software download and enable the card, enter ENL MSDL x
FDL. This command forces the download of the MSDL base code and the
configured peripheral software even if it is already resident on the card.
The card is then enabled.
Toenable a disabled MSDL and its ports, enter ENL MSDL x ALL. This
command downloads all peripheral software (if required) and enables any
configured ports on the card. This command can be issued to enable some
manually disabled ports on an already enabled MSDL.
Disabling the MSDL
Todisable an MSDL card, enter DIS MSDL x.
Todisable the MSDL and all its ports, enter DIS MSDL x ALL.
Resetting the MSDL
Toreset an MSDL and initiate a limited self-test, the MSDL must be in a
manually disabled state. To perform the reset, enter RST MSDL x.
Displaying MSDL status
Todisplay the status of all MSDL cards, enter STAT MSDL.
Todisplay the status of a specific MSDL, enter STAT MSDL x. The status
of the MSDL, its ports, and the operation of each port appears.
The command STAT MSDL x FULL displays all information about an
MSDL (card ID,bootload fir mware version,base code version, base code
state, operation state, date of base code activation) as well as the version,
state, and activation date for each card operation.
Self-testing the MSDL
Toperform extensive self-testing of an MSDL, enter SLFT MSDL x. This
test can be activated if the card is in the manually disabledstate. If the test
passes, the system outputs the card ID and a pass message. If it fails, the
system displays a message indicating which test failed.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.