312 NT5D33 and NT5D34 Lineside E1 Interface cards
terminate at the end of the time period or when a Stop Test command
is issued. Only Stop Test stops a test with a duration selection of 99;
however,the STOP command terminates a test set to any duration from one
to 99. After entering the test number, a prompt similar to Figure 77 "Test
parameters screen" (page 312) appears.
Figure 77
Test parameters screen
Before a test is run, be sure to verify that the card is disabled, as the tests
interfere with calls currently in process.
During a test, if an invalid word is received, this is recorded by a failure
peg counter. The peg counter has a limit of 65,000. At the end of the test,
the TestResults message indicates howmany failures, if any, occurred
during the test.
Table127 "MMI Tests" (page 312) shows which test to run for the associated
equipment.
Table127
MMI Tests
Test number Equipment Tested Test Description
1LEI Local loopback
2E1 link, LEI, and E1
network External loopback
3CPE device and E1
network Network loopback
Test1, localloopback, loops the E1 link signaling toward itself at the
backplane connector. Testdata isgenerated and received on all timeslots.
If this test fails, it indicates that the LEI is defective. Figure 78 "MMI Local
loopback test" (page 313) illustrates how the signaling is looped back
toward itself.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.