NT8D22 System Monitor 97
Settings
Frequency Amplitude P1 P2 P3
25 Hz 86 V ac open 2–5
8–11 open
50 Hz 70 V ac 1–4
7–10 open open
50 Hz 80 V ac 3–6
9–12 open open
NT8D22 System Monitor

The master system monitor, located in the column with CP 0, must be

numbered 0. Slave system monitors are numbered from 1 to 63.

For examples of system monitor option settings in basic configurations, see

"Sample settings for NT8D22 System Monitors."

Configure the system monitor in Remote Peripheral Equipment (RPE)

columns as slaves. There is no serial connection between RPE columns.

Tabl e 36
NT8D22 SW1
Position
SW1 function 1 2 3 4 5 6 7 8
Not used
Meridian 1 columns only on
off
Position 1 is OFF (Meridian 1
columns only)
Not used
Position 1 is ON, master column
contains CP:master
slaves
off
off
on
off
DC-powered system
AC-powered system on
off
PFTU is activated by this column
due to over-temperature
PFTU is not activated by this
column
on
off
Position 1 is OFF (Meridian 1
columns only)
Not used
Not used
off
on
off