816 NT8D41AA Serial Data Interface Paddle Board
Table317
SDI paddle board baud rate switch settings
Port 1 – SW2 Port 2 – SW3
Baud
rate 12341234
150 off off on on off off on on
300 off on off on off on off on
600 off off off on off off off on
1200 off on on off off on on off
2400 off off on off off off on off
4800 off on off off off on off off
9600 off off off off off off off off
DTE/DCE/Fiber mode
Each serial port can be configured to connect to a terminal (DTE
equipment), a modem (DCE equipment), or a Fiber Superloop Network card.
Instructions for setting the switches SW5, SW6, SW7, and SW8 are shown
in Table318 "NT8D41AA DTE/DCE/Fiber switch settings" (page 816).
Table318
NT8D41AA DTE/DCE/Fiber switch settings
Port 1 – SW5 Port 1 – SW6
Mode 1 2 3 4 56123456
DTE (terminal) on on on on on on off off off off off off
DCE (modem) off off off off off off on on on on on on
NT1P61 (Fiber) on on on on on off off off on on on on
Port 2 – SW7 Port 2 – SW8
DTE (terminal) on on on on on on off off off off off off
DCE (modem) off off off off off off on on on on on on
NT1P61 (Fiber) on on on on off off off off on on on on
Software service changes
Once the NT8D41 SDI paddle board has been installed in the system,
the system software needs to be configured to recognize it. This is done
using the Configuration Record program LD 17. Instructions for running
the Configuration Record program are found in Software Input/Output
Reference — Administration (NN43001-611).