890 NTAK102.0 Mb DTI card
The external interconnection is through a 50-pin MDF connector with a
NTBK05 carrier cable A0394217.
The external connection is through a 50-pin MDF connector with the
NTBK05 carrier cable A0394217.
CEPT interface
For the Conference ofEuropean Postal Communications (CEPT) interface,
the connection to the external digital carrier is through the NT5K85 DTI
cable assembly. It converts the 120 ohms D-connector to 75ohms coaxial
cable. The impedance is switch set. The switch-settings table at the end
of this chapter describes the options. See Table 367 "2 MB DTI switch
options" (page 890).
If a coaxial interface is required, use NT5K85 in conjunction with the
NTBK05.
Table367
2 MB DTI switch options
Switch Off
(Switch Open) On
(Switch Closed)
S1-1 ——
S1-2 CC Enabled CC Disabled
S2-1 120 ohms 75 ohms
S2-2 75 ohms 120 ohms
S3-1 non-French Firmware French Firmware
S3-2 ——
For the Conference ofEuropean Postal Communications (CEPT) interface,
the connection to the external digital carrier is through NT5K85 DTI cable
assembly A0392021. It converts the 120ohm D-connector to 75ohm coax.
The impedance is switch set. See the switch-settings table at the end
of this chapter for options.
If a coax interface is required, use NT5K85 in conjunction with the NTBK05.
For the Conference ofEuropean Postal Communications (CEPT) interface,
the connection to the external digital carrier is through the NT5K85 DTI
cable assembly. It converts the 120 ohms D-connector to 75ohms coaxial
cable. The impedance is switch set. The switch-settings table at the end of
this chapter describes the options. See Table 369 "2 MB DTI switch options"
(page 902) "Switch settings" (page 901).
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.