828 NT8D41BA Quad Serial Data Interface Paddle Board
Port 1 — SW 3 Port 1 — SW 2
Mode 1 2 3 456123456
NT1P61 (Fiber) on on on on on off on on on off on off
Port 4 — SW 9 Port 4 — SW 8
DTE (terminal) on on on off on off off on off on off on
DCE (modem) off off off on off on on off on off on off
NT1P61 (Fiber) on on on on on off on on on off on off
Software service changes
Once the NT8D841BA QSDI paddle board has been installed in the
system, the system software needs to be configured to recognize it, using
the Configuration Record program LD 17. Instructions for running this
program are found in Software Input/Output Reference — Administration
(NN43001-611).
Some of the prompts that are commonly used when running the
Configuration Record program LD 17 are shown in Table325 "LD 17 -
Prompts to configure the NT8D841Ba paddle board." (page 828) These
parameters must be set for each port if both ports are being used.
Table325
LD 17 - Prompts to configure the NT8D841Ba paddle board.
Prompt Response Description
REQ: CHG Change configuration
TYPE: ADAN Configurationtype
ADAN NEW TTY x
NEW PRT x
Define a new system terminal (printer) port as device x, where x
= 0 to 15.
CTYPE SDI4 Quad port card
DES XQSDI Quad density QSDI paddle board.
USER xxx Enter the user of port x. The values that can be entered depend
on the software being used. See the Software Input/Output
Reference — Administration (NN43001-611) for details.
XSM (NO)YES Port is used for the system monitor.
ApplicationsThe NT8D41BA Quad Serial Data Interface paddle board is used to connect
the switch to a variety of communication devices, printers, and peripherals.
Any RS-232-C compatible device can be connected to either of the card’s
two serial ports.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.