756 NT8D15 E and M Trunkcard
In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250 ms,
wink start, off hook/on hook signal to the calling office.
Table271
Operation mode
Operation mode Start arrangement
Immediate start IMM
Delay dial DDL
Wink start WNK
The far-end initiates calls as follows:
The ground is placed on the E lead inE and M signaling.
Dial pulses are subsequently applied from the far-end as ground open
on the E lead.
If the far-end is equipped forsending, the system can operate in any
mode (immediate start, delay dial, or wink start), as assigned on a start
arrangement basis. See Table 272 "Operation Mode" (page 756).
In immediate start mode, there is no start signal from the called
office. The seizure signal (off hook supervisory state) from the
far-end should be at least 150 ms. At the end of the seizure signal,
the far-end can start pulsing after the standard delay (normally 70
ms minimum).
In delaydial mode,a 256–384 ms off hook/on hook signal is returned
to the far-end immediately after receipt of the seizure signal. When
the far-end detects the on hook signal (start signal), the far-end can
start pulsing after the standard delay (normally 70 ms minimum).
In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250 ms,
wink start, off hook/on hook signal to the calling office.
Table272
Operation Mode
Operation mode Start arrangement
Immediate start IMM
Delay dial DDL
Wink start WNK
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.