720 NT8D15 E and M Trunkcard
The E and M Trunk card mounts in any IPE slot. The line interface and
common multiplexing circuitry is mounted on a 31.75 cm by 25.40 cm (12.5
in. by 10 in.) printed circuit board.
The E and M Trunkcard connects to the IPE backplane through a 160-pin
connector shroud. The backplane is cabled to the I/O panel on the rear of
the module, which is then connected to the Main Distribution Frame(MDF)
by 25-pair cables. Telephonelines fromstation equipment cross connect to
the OPS analog line card at the MDF using a wiring plan similar to that used
for line cards. See Communication Server 1000M and Meridian 1 Large
System Installation and Configuration (NN43021-310) for termination and
cross connect information.
SeeFigure 223 "E and M Trunkcard - faceplate" (page 721) for an illustration
of the faceplate on the E and MTrunk card. The words "Dict Trk" appear on
the faceplate label because earlier versions of this card provided dictation
trunk connections for third-party equipment.
The faceplate of the card is equipped with a red LED. When an E and M
Trunkcard is installed, the LED remains lit for 2 to 5 seconds while the
self-test runs. If the self-test completes successfully, the LED flashes three
times and remains lit. When the card is configured and enabled in software,
the LED goes out. If the LED continues to flash or remains weakly lit,
replace the card.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.