Operation 47
Figure 10
IPE trunk cards installed in an NT8D37 IPE module
3Install the cable that connects the backplane connector onthe IPE
module to the module I/O panel.
4Connect a 25-pair cable from the module I/O panel connector to the
Main Distribution Frame (MDF).
5Connect the trunk card output to the selected terminal equipment
at the MDF.
6Configure the individual trunk interface unit using the Trunk
Administration program (LD 14) and the TrunkRoute Administration
program (LD 16).
—End—
Once these steps are complete, the trunk card is ready foruse.
Operation This section describes how trunk cards fit into the CS 1000E, CS 1000M,
and Meridian 1 architecture, the buses that carry signals to and from the
trunk cards, and how they connect to terminal equipment. See Ta ble 7
"Differences between IPE parameters" (page 48) for IPE parameters.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.