QPC528 CO/FX/WATSTrunk cards 109
Tabl e 48
QPC559, QPC560 double density
Double density—Unit 0/1/2/3
H17/H3/A17/A3 switch
Application 1 2 3 4 56
Outgoing ANI only:
loop pulsing off off off off off off
battery and groundpulsing off off off off on off
Other than outgoing ANI on off on off on off
Jumpers (QPC560) Units 0/1/2/3
600 3/4resistive impedance connect pins 1 and 2
3-component complex impedance connect pins 2 and 3
QPC528 CO/FX/WATSTrunk cards

Table49 "QPC528 Trunk cards switch and jumper settings" (page 109) lists

switch and jumper settings for options available.

Tabl e 49
QPC528 Trunkcards switch and jumper settings
Switch Settings
Switch S1 (location A23)
Switch position: 1 2 3 4 5678
on off on off on off on off
Unit 0, Switch S2 (Location E29)
Unit 1, Switch S3 (Location E9)
Unit 2, Switch S4 (Location A28)
Unit 3, Switch S5 (Location A10)
Switch position: 1 2 3 4 5678910
Trunk type:
Loop start off on off off on off off off
Ground start off on on on on off off off
Metering:
Second pair (M, MM) or off off
Third wire, battery on M or off on
Third wire, ground on M on off
Jumper Settings
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.