Configuring the SDI paddle board 815
Configuring the SDI paddle board
Configuring the SDI paddle board to work in a Meridian 1 system consists of
setting these option switches for each serial port:
Port address
Baud rate
DTE/DCE/Fiber mode
The SDI paddle board has seven option switches,SW 2–8. Figure 268 "SDI
paddle board option switch locations" (page 817) identifies the location of
option switches on the SDI paddle board. Instructions for setting these
switches are in the section that follows.
Once the board has been installed, the system software must be configured
to recognize it. Instructions for doing this are found in ""Software service
changes" (page 808)".
Option switch settings
Address
Address select switch SW4 and logic on the card alwaysaddress the two
UARTsusing a pair of addresses: 0 and 1, 2 and 3 through 15 and 16. The
settings for this switch are shown in Table316 "SDI paddle board address
switch settings" (page 815).
Table316
SDI paddle board address switch settings
Address Switch SW4
Port 1 Port 2 1 2 3 4
01off on on on
23off on on off
45off on off on
67off on off off
89off off on on
10 11 off off on off
12 13 off off off on
14 15 off off off off
Baud rate
Switches SW2 and SW3 determine the baud rate for each individual port.
The settings for these switches are shown in Table317 "SDI paddle board
baud rate switch settings" (page 816).