474 NT7D16 Data Access card
Disabled—On with DTR (normal)
Enabled—Off with DTR (modes 8 or 12, and no DTR for 5 seconds)
Auto Baud
Variable (use auto baud rate)
Fixed (use baud rate selection only)
Baud rate
— 110
— 150
— 300
— 600
— 1200
— 2400
— 4800
— 9600
— 19200
Operating mode
— DCE
— DTE
Equipment type
Terminal(send prompts/replies)
Host (suppress prompts/replies)
Long Break Detect
In Table161 "Clock Controller options - summary" (page 353) and Figure
104 "MSDL switch setting example" (page 402), the rectangles represent
the settings of service change parameters in LD11 that affect the desired
function. The diamonds represent the logical DAC operatingmode
decisions.
Upload parameters
The system can, at any time, request information from a DAC port. The
uploaded parameters contain information about the individual card (card
type, order code, release information), as well as the status of the configured
operating parameters. Because the dialogue operations of data calls can
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.