Introduction 907
Tracking mode
In tracking mode, one or more DTI/PRI cards supply a clock reference to the
NTAK20clock controller daughterboard. When operating in tracking mode,
one DTI/PRI card is defined as the Primary Reference Source (PREF) for
clock synchronization. The other DTI/PRI card is defined as the Secondary
Reference Source (SREF). PREF and SREF are definedin LD 73.
There are two stages to clock controller tracking:
tracking a reference
locking on to a reference
When tracking a reference,the clock controller uses an algorithm to match
its frequency to the frequency of the incoming clock. When the frequencies
are almost matched, the clock controller locks on to the reference. The
clock controller makes small adjustments to its own frequency until both the
incoming and system frequencies correspond.
If the incoming clock reference is stable, the internal clock controller
tracks it, locks on toit, and matches frequencies exactly. Occasionally,
environmental circumstances cause the external or internal clocks to vary.
When this happens, the internal clock controller briefly enters the tracking
stage. The green LED flashes until the clock controller is locked on to the
reference again.
If the incoming reference is unstable, the internal clock controller
continuously tracks,and the LED continuously flashes green. This condition
does not present a problem. It shows that the clock controller is continually
attempting to lock onto the signal. If slips occur, there is a problem with the
clock controller or the incoming line.
There are two stages to clock controller tracking:
tracking a reference
locking on to a reference.
When tracking a reference, the clock controller uses an algorithm to
match its frequency to the frequency of the incoming clock. When the
frequencies are very near to being matched, the clock controller is locked
on to the reference. The clock controller makes small adjustments to its own
frequency until both the incoming and system frequencies correspond.
If the incoming clock reference is stable,the internal clock controller tracks
it, locks onto it, and matches frequencies exactly. Occasionally,however,
environmental circumstances cause the external or internal clocks to drift.
When this happens, the internal clock controller briefly enters the tracking
stage. The green LED flashes momentarily until the clock controller is
locked on to the reference once again.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.