444 NT7D16 Data Access card
Programing DACfor mode 14 in service change LD 11
The DAC must be configured as R232 since Autodial, Speed Call, and
Display commands are likely to be used.
Mode 15
This mode provides a "virtual leased line" and the meaning of the "Forced
DTR" switch is re-defined.
This mode should be selected when the DACis connected to a terminal
(DTE) and continuous Hotline call origination is required. In this mode,
the DAC repeatedly tries to Hotline to the Autodial DN as long as DTR is
ON. This operation is similar to having a leased line feature,where the
connection between two extensions is always established. When the
DAC tries to Hotline to a busy Data Module, it activates Ring Again and
the connection is established as soon as the called unit is free. After
establishing the data call, if the called unit releases the call for any reason,
the DACautomatically tr ies to Hotline again to reestablish the call.
If the data unit being called does not answer the Hotline call, the DACtries
to place another Hotline call once every 40 seconds until the called unit
answers. This mode is recommended only when a permanent connection
between a terminal and another data unit is required. The baud rate of the
Hotline call is determined by the AUTB and BAUD parameters in LD 11.
The status of CTS, DSR, and DCD is controlled in a similar manner as
described in mode 13.
Programing DACfor mode 15 in service change LD 11
The DAC must be configured as R232 since Autodial, Speed Call, and
Display commands are likely to be used.
Mode selection baud rates
The AUTB and BAUDparameters in LD 11 provide two functions for calls
originated from a DAC:
Provide a wayto select a baud rate of a Hotline call. The DAC starts the
Hotline operation without receiving a <CR> for autobaud.
Set the DACto operate at a fixed baud rate. The DACdoes not retur n
the menu or Hotline unless a <CR> is received at the selected baud
rate. Normally the DAC should be selected to operate at autobaud.
Note: If AUTB is set to ON, theBAUD parameter is not prompted. If
AUTBis set to OFF,you may select a fixed baud rate in response to the
prompt BAUD.
When the DACreceives a call, it adapts to the caller’s baud rate.