Installation and configuration 197
MMI Master or Slave
This setting is used only if daisy-chaining the cards to the MMI terminal or
modem. This setting determines whether this card is a master or a slave in
the MMI daisy-chain. Select the master setting if this card is the card that is
cabled directly into the MMI terminal or modem; select the slave setting if
this card is cabled to another Lineside T1 card in a daisy chain.
Table91 "Lineside T1 card-T1 Switch 1 (S1) dip switch settings" (page
197) through Table94 "Lineside T1 card - CPE or CSU distance dip switch
settings (Switch S2, positions 3 - 5)" (page 198) describe the proper dip
switchsettings for each type of T1 link. After the card has been installed, the
MMI displays the DIP switchsettings the command Display Configuration
is used. See "Functional description" (page 391) for details on how to
invoke this command.
Tabl e 91
Lineside T1 card-T1 Switch 1 (S1) dip switch settings
Dip Switch
Number Characteristic Selection
1MMI port speed selection On = 1200 baud
Off = 2400 baud
2T1 signaling On = Ground start
Off = Loop start
3–6 XPEC Address for the Lineside T1 card See Table 92 "Lineside
T1 card - XPEC address
dip switch settings (Switch
S1, positions 3 - 6)" (page
197).
7Not Used Leave Off
8Reserved for SL-100 use Leave Off
Tabl e 92
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)
XPEC
Address S1 Switch
Position 3 S1 Switch
Position 4 S1 Switch
Position 5 S1 Switch
Position 6
00 Off Off Off Off
01 Off Off Off On
02 Off Off On Off
03 Off Off On On
04 Off On Off Off
05 Off On Off On
06 Off On On Off