940 NTAK792.0 Mb PRI card
Table393
Carrier shield grounding switch settings
Switch Carrier Pair On Off
S4-1 Rx shield Open GND
S4-2 Tx shield Open GND
NTAK79provides for the capability of selectively grounding the shield of
the Tx and/or Rx pairs of the carrier. Closing (down) the on-board switch
applies FGND to the appropriate carrier cable shield. The switch settings
are shown below.
Table394
Carrier shield grounding switch settings
Switch Carrier Pair On Off
S4-1 Rx shield Open GND
S4-2 Tx shield Open GND
The NTAK79card provides the capability of selectively grounding the shield
of the Tx and/or Rx pairs of the carrier. Closing (down) the on-board switch
applies FGND to the appropriate carrier cable shield. The switch settings are
shown in Table395 "Carrier shield grounding switch settings" (page 940).
Table395
Carrier shield grounding switch settings
Switch Carrier Pair On Off
S4-1 Rx shield Open GND
S4-2 Tx shield Open GND
Receiver functions
The receiver extracts data and clock from an AMI (Alternate Mark Inversion)
coded signal and outputs clock and synchronized data. The receiver is
sensitive to signals over the entire range of cablelengths and requires
no equalization. The clock and data recovery meets or exceeds the
jitter specifications of the CCITT recommendation G.823, and the jitter
attenuation requirements of the CCITT recommendation G.742. This
provides jitter attenuation increasing from 0 dB to 60 dB overthe frequency
range from about 6 Hz to 6 KHz.
The receiver extracts data and clock from an AMI (Alternate Mark Inversion)
coded signal and outputs clock and synchronized data. The receiver is
sensitive to signals over the entire range of cablelengths and requires
no equalization. The clock and data recovery meets or exceeds the
jitter specifications of the CCITT recommendation G.823 and the jitter
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.