Functional description 341
Note in all cases - If an NT8D72BA/NTCK43 card is being replaced by
a DDP2 card, the D-channel Handler can be reconnected to the DDP2
card, or removed if an onboard NTBK51DDCH card is used. Also, DIP
Switches in the NT5D97 must be set properly before insertion. NT5D97 has
a different DIP Switch setting from NTCK43AB. Refer to "NT5D97AA/AB
DIP switch settings" (page 341) for DIP switch setting).
NT5D97AA/AB DIP switch settings
The the NT5D97 DDP2 card is equipped with 6x2 sets of DIP switches for
trunk parameters settings for port0 and port1 respectively. Additionally,
the DDP2 card is equipped with one set of four DIP switches forthe Ring
Ground setting. The NT5D97AA/AB has one set of eight DIP switches and
NT5D97AD has two sets of ten DIP switches forthe D-channel Handler
parameters setting.
The DIP switches are used for the setting of default values of certain
parameters. Firmware reads the general purpose switches, which sets the
default values accordingly.
Table143
DIP switch settings for NT5D97AA/AB
Card Trunks
0 and 1 Port 0 Port 1 Trunk 0 Trunk1
ENB/DSB
mounted on the face plate S1
Ring Ground S2
MSDL S3
TX Mode S4 S10
S5 S11
S6 S12
LBO Setting
S7 S13
Receiver Interface S8 S14
General Purpose S9 S15
The following parametersare set by DIP switches. The boldface font shows
the factory set-up.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23May 2008
Copyright© 2003-2008, Nor tel Networks
.