718 NT8D15 E and M Trunkcard
Table268
Trunkand signaling matrix
Trunk types
Signaling RLM/RLR Tie PAG CSA/CAA/CAM
2-wire E and M Yes Yes Yes Yes
4-wire E and M Yes Yes No
Note: Yes
for 11C and
11C mini.
Yes
Legend:
RLM Release Link Main
RLR Release Link Remote
CSA Common Control Switching Arrangement
CAA CommonControl Switching Arrangement with Automatic Number Identification (ANI)
CAM CentralizedAutomatic Message Accounting (CAMA) trunk
This chapter outlines the characteristics, application and operation of the
NT8D15 E and M TrunkCard. The information is intended to be used as a
guide when connecting customer-provided apparatus to the trunk circuit.
NT8D15 E and M TrunkCard has fouridentical trunk circuits. Each circuit
can be configured independently by software control. The trunk circuits on
the card support the following types of trunks:
two-wire E and M type I signaling trunks (non-ESN)
two-wire dial repeating trunks
two or four wire tie trunks
four-wire E and M type I and II signaling type II trunks (ESN and
Non-ESN applications)
Paging (PAG)
TypeI signaling (as on the two-wire E & M trunk) utilizes two signaling wires
plus ground. Type II signaling utilizes tow pairs of signaling wires and is
used by most electronic switching systems.
Table269 "Supported trunk and signaling matrix" (page 719) shows a
matrix of the trunk types and signaling supported by the NT8D15 E and M
TrunkCard.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.