350 NT5D97 Dual-port DTI2 PRI2 card
MSDL external card
Table159
Switch settings for MSDL external card
Switch number Function
S9_1-10 X
S8_1-10 X

Use Table160 "Switch setting for MSDL external card" (page 350) to set

the card address.

Table160
Switch setting for MSDL external card
Switch Setting
DNUM (LD 17) 1234
0OFF OFF OFF OFF
1ON OFF OFF OFF
2OFF ON OFF OFF
3ON ON OFF OFF
4OFF OFF ON OFF
5ON OFF ON OFF
6OFF ON ON OFF
7ON ON ON OFF
8OFF OFF OFF ON
9ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
Architecture
Clock operation

There are two types of clock operation - tracking mode and free-run mode.

Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.