302 NT5D33 and NT5D34 Lineside E1 Interface cards
Figure 66
Set Simple (S S) no screen
Figure 67
Set Simple (S S) yes screen
Set Mode
At the SET MODE (S M) command, the MMI prompts the user with the
current signaling mode, either Default (AustralianP2) or Table (of bit values.)
Entering a <CR> accepts the current value, or the user can type in 1 to
revert to the Default, or 2to edit the table entries. See Figure 68 "Set Mode
screen" (page 302). If the user selects default, then the A/B Bit values is
reset to the Default values.
Responding to the MMI’s Set Mode prompt with "1" also results in the
line, "Signaling Bits set to Default,"asinFigure 68 "Set Mode screen"
(page 302).
Figure 68
Set Mode screen
However,responding to this prompt with 2selects "Table" and allows the
user to set the A/B Bit Mode to whatever configuration the user chooses.
If "Table"is selected, the individual table values are prompted for. See
Figure 69 "Set Mode (S M): Tablescreen" (page 303) and Figure 70 "Set
Mode (S M): Tablescreen" (page 304). After each value is displayed,enter
<CR> to do the following:
accept the current value
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.