NT8D14 Universal Trunkcard 93
NT8D14 Universal Trunk card

Table30 "NT8D14 vintage AA jumper strap settings" (page 93) through

Table34 "NT8D14 vintages BA/BB cable loop resistance and loss" (page

95) list option settings for the NT8D14 Universal Trunkcard.

Tabl e 30
NT8D14 vintage AA jumper strap settings
Modes Location Jumper strap
Central Office (CO) J1, J2 off
2-way tie trunk (loop dial repeat) J1, J2 off
2-way tie trunk (outgoing/incoming dial) J1, J2 off
Recorded announcement (RAN) J1, J2 off
Paging trunk J1, J2 off
Japan CO/DID operation J1, J2 off
DID operation: loop length > = 2000 3/4J1, J2 on
DID operation: loop length < 2000 3/4J1, J2 off
Note 1: off = no strap present.
Note 2: Locations (J1, J2) apply to all eight units.
Tabl e 31
NT8D14 vintages BA/BB jumper strap settings-factory standard
Jumper strap settings
Trunk types Loop length J1.X J2.X J3.X J4.X
CO/FX/WATS
2-way tie (LDR)
2-way tie (OAID)
Zero–1524 m (5000 ft)
DID Zero–600ohms
RAN: continuous
operation mode
Paging
Not applicable: RAN and
paging trunks should not
leave the building.
Off Off 1–2 1–2
Note: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; "X" indicates the unit
number, 0–7. "Off" indicates that no jumper strap is installed on a jumper block. Storeunused straps
on the universal trunk card by installing them on a single jumper pin as shown below:
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.