40 Overview
the transmit B bit between 0 and 1 (0 during ring on, 1 during ring off), and
ground on the tip lead by setting the transmit A bit to 0. When an incoming
call is answered (by the terminal equipment going off-hook), the terminal
equipment simulates tripping the ringing and shutting off ringing by causing
the lineside T1’s receive A bit to change from 0 to 1. The Lineside T1
card responds to this message by simulating loop closure by holding the
transmit B bit constant at 1.
Outgoing Calls During outgoing calls from the terminal equipment, a
channel is seized when the terminal equipment goes off-hook, simulating a
ground to the ring lead toward the Lineside T1 card by causing the lineside
T1’s receive B bit to change from 1 to 0. In turn, the Lineside T1 card
simulates grounding its tip lead by changing the transmit A bit to 0. The
terminal equipment responds to this message by removing the ring ground
(lineside T1’s receive B bit is changed to 1) and simulating open loop at the
terminal equipment (lineside T1’s receive A bit is changed to 0).
Call disconnect from far end PSTN, private network or local
station While a call is in process, the farend might disconnect the call.
If the Lineside T1 port has been configured with the Supervised Analog
Line (SAL) feature, the Lineside T1 responds to the distant end disconnect
message by opening tip ground. This causes the Lineside T1 card to
change the transmit A bit to 1. When the terminal equipment sees the
transmit A bit go to 1, it responds by simulating open loop causing the
lineside T1’s receive A bit to change to 0. The call is ter minated and the
interface is once again in the idle condition.
For the Lineside T1 card to support distant end disconnect in ground start
mode, the following configuration parameters must exist:
•The Supervised Analog Line (SAL) feature must be configured for each
Lineside T1 port.
Note: By default, the SAL feature opens the tip side for 750 m/s in
loop start operation. This is configurable in 10 m/s increments.
•In order to detect distant end disconnect for calls originating on the
Lineside T1 card, the "battery reversal" feature within the SAL software
must be enabled. Enabling the battery reversal feature doesnot provide
battery reversal indication when a call is answered; it only provides
battery reversal indication when a call is disconnected.
•In order to detect distant end disconnect for calls terminating on the
Lineside T1 card, the "hook flash" feature within the SAL softwaremust
be enabled.
•In order to detect distant end disconnect for calls originating and
terminating on the Lineside T1 card, both the "battery reversal" and
"hook flash" features within the SAL software must be enabled.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23May 2008
Copyright© 2003-2008, Nor tel Networks
.