1078 NTRB21 DTI/PRI/DCH TMDI card
Digital Trunkingrequires synchronized clocking so that a shift in one clock
source results in an equivalent shift of the same size and direction in all
parts of the network.
On CS 1000 systems, synchronization is accomplished with the NTAK20
clock controller circuit card. The clock controller circuitry synchronizes the
CS 1000 to an external reference clock and generates and distributesthe
clock to the system. The CS 1000 can function either as a slave to an
external clock or as a clocking master to the network.
The NTAK20ADversion of the clock controller meets AT&T Stratum 3 and
Bell Canada Node Category D specifications. The NTAK20BDversion
meets CCITT stratum 4 specifications. "Electrical specifications" (page
1005)
ATTENTION
IMPORTANT!
Each Media Gatewaythat has adigital trunk mustuse a clock controller clocked
to an external reference clock.
Note: Clocking slips can occur between systems that are clocked from
different COs, if the COsare not synchronized. The slips can degrade
voice quality.
Clock rate converter
The 1.5 Mb clock is generated by a Phase-LockedLoop (PLL). The PLL
synchronizes the 1.5 Mb DS1 clockto the 2.56 Mb system clock through the
common multiple of 8 kHz by using the main frame synchronization signal.
The 1.5 Mb clock is generated by a phase-lockedloop (PLL). The PLL
synchronizes the 1.5 Mb DS1 clockto the 2.56 Mb system clock through the
common multiple of 8 kHz by using the main frame synchronization signal.
The 1.5 Mb clock is generated by a Phase-LockedLoop (PLL). The PLL
synchronizes the 1.5 Mb DS1 clockto the 2.56 Mb system clock through the
common multiple of 8 kHz by using the main frame synchronization signal.