76 Acceptance tests
2Testand enable an MFS loop:
LD 46
MFS loop
(on the NT8D17 Conference/TDS card, the TDS/MFS loop is the
even loop of the conference/TDS loop pair)
Note: The conference/TDS card is not enabled automatically
when it is inserted. You must enable the card with the command
ENLX. (This command is used in LD 34 and LD 46 to address
even loops and in LD 38 to address odd loops.) Enabling the
loops with the command ENLL does not enable the hardware
for the card.
If the system response is other than OK, see Software Input/Output
Reference — Administration (NN43001-611) to analyze the
messages.
3Access the system from a maintenance telephone; then enter:
LD 46
Give the system approximately 20 seconds to load the program.
See "Communicating with the Meridian 1" in Software Input/Output
Reference— Administration (NN43001-611) for details on accessing
the system from a maintenance telephone.
4Obtain 10-second bursts of digits 1 to 9, 0, and 11 to 15 (in that
order) for all digits on the specified loop: TONE loop ALL
Each burst should sound different. If the bursts do not sound
different, replace the card.
5End the session in LD 46:
****
—End—
Multifrequency signaling cards
Procedure 7
Testingmultifrequency signaling cards
Step Action
Use this procedure to test a multifrequency signaling card.
1Log into the system:
LOGI (password)
2Testand enable the specified unit:
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.