Safety informa tion 317
Safety data sheet Océ TDS600 printer
Note: The contents of this safe ty data sheet is subject to the discla imer on
page 316 of this manual.

PRODUCTSAFETY DATASHEET

Océ-(UK),Ltd

Number E-691-a-UK
Date May1999

Copyright© 1999 Océ-Technologies B.V., Venlo,NL

Model Océ9600 Printer-engine
Description Electrostaticprinter, instant printing, console model, plain paper, organic photoconductive
drum,powder toner.
Max.process speed 5m/min.
Dimensions Width 1400 mm
Depth 753 mm
Height 1470 mm
Weight 250 kg 50kg (extra rolldrawer) 25 kg (extrasheet feeder)
Voltage 230 V
Frequency 50-60 Hz
Current-rated 7,5 A
Current-max 10 A
Powerconsumption, operation 1470 W
Powerconsumption, standby 50 W
EPAENERGYSTA R ¨
*Power consumption, lowpower 180 WRecovery time < 3 seconds
Mainsconnection Cable with plug
Safetyclass I (IEC536) Protective earth connection
Protectionclass IP 20 (IEC529)
Soundpressure level
(atoperator/bystander
position)
Standby: In operation:
30dB(A) mainbody50 dB(A);
incl.optionals 57 dB(A);
mpulseLi= 3 dB(A)
Soundpower level 51dB(A) mainbody63 dB(A);
incl.optionals 75 dB(A)
Radiointerference Complieswith Directive 89/336/EEC
Radiation Belowthe Threshold Limit Value for UV radiation (TLVlist of ACGIH)
Heatemission Standby50 W; in operation 1470 W
Ozoneemission 0,004 mg/min at continuous operation
Roomvolume Recommendation: min. 50 m3
Roomventilation Recommendation:min.25 m3/h (natural ventilation)
(Forheat evacuation extra ventilationmay be necessary)
Usesimulation at random
operation Witha room volume and ventilation as recommended and a daily volume of 210 m (much
morethan average) the use simulation at random operation gives the followingozone
concentrations:
-Time weighted average 0,001 mg/m3(0,00o5 ppm)
-Peak 0,002 mg/m3(0,0005 ppm)
ThresholdLimit Value/Occupational Exposure Limit
(TimeWeighted Average) for ozone 0,2 mg/m3(0,1 ppm)
OdourPerception Limit for ozone 0,04 mg/m3(0,02 ppm)
Consumables OcéOPC Drum,(Océ Material Safety Data Sheet E-218)
OcéB5 Toner (Océ Material Safety Data Sheet E-199)
OcéD5 Developer (Océ Material Safety Data Sheet E-200)
OcéCopying Materials. This apparatus is suitable for processing recycling paper which
complieswith the requirements of ENV 12281.
Additionalsafety information Theozone Þlter does not haveto be replaced for keeping the ozone concentration in the
workplacebelow 0,04 mg/m3(the life of the Þlter equals that of the apparatus)
CE-Compliance Approvedaccording to Approvedaccording to
LowVoltage Directive EMC Directive
73/23/EEC 89/336/EEC