Safety informa tion 325
Note: The contents of this safe ty data sheet is subject to the discla imer on
page 316 of this manual.
MATERIALSAFETY DATASHEET Number E-218-a-UK
(93/112/EECand ISO 11014-1) Date April1998
Page 2of2
OcéOPC Drum Part No. 2912571, Océ ES102 OPC Part No. 7069008
9. Physical and chemical properties
Explosionlimits (dust explosion) LEL N.A. UEL N.A. Flash point (
o
C) N.A.
Appearanceand odour browncoloured aluminium cylinder Ignitiontemperature(
o
C) N.A
Boilingpoint (
o
C) N.A Density(g/cm3)2,7
Vapourdensity (air = 1) N.A. Meltingpoint (
o
C) N.A.
Solubilityin water Insoluble Evaporationrate (butyl acetate =1) N.A.
Vapourpressure N.A. %Volatile 0
Othercharacteristics N.A. pH(solution) N.A.
10. Stability and reactivity
Thermaldecomposition None at intended use
Hazardousdecomposition products Noneat intended use
Hazardousreaction Noneatintended use
11. Toxicological information
12. Ecological information
Thisproduct is not biodegradable.
Theingredients are not classi?ed as ecologically hazardous. No adverse environmental effects are expected.
13. Disposal considerations
Thedrum will be returned to Océ for re-use.
14. Transport information
Thisproduct is not classified as a dangerous substance according to the international transport regulations.
15. Regulatory information
Thisproduct is an article and contains no dangerous substances. Therefore, indications of special risks or safety advice on the packing are
notprescribed for this product.
16. Other information
Copyright© 1998 Océ-TechnologiesB.V. Venlo, NL
Use:photoconductor for printers and copiers.
Inhalation N.A.
Skin Noadverse health effects are expected. (Based on toxicologicalliterature on the ingredients of this product)
Eyes N.A.
Ingestion N.A.
Mutagenicity Nomutagenicity detected in Ames test. None of the ingredients is listed as mutagenic or carcinogenic.