OcéPower Logic: Settings Editor (forthe key operator) 187
Zoom steps
The Key-Operator can change the 8 zoom steps in the range from 25.0% -
400.0% in steps of 0.1%. There are 4 z oom steps to reduce and 4 zoom steps
to enlarge (see figure 107). The zoom step 100.0% can not be changed.
[107]Zoom steps for keyoperators
The defaults for the 8 zoom ste ps are:
Reduction step 1: 70.7%
Reduction step 2: 50%
Reduction step 3: 35.5%
Reduction step 4: 25%
Enlargement step 1: 141.4%
Enlargement step 2: 200%
Enlargement step 3: 282.8%
Enlargement step 4: 400%
Timers
Thereare three, scanner related, timer settings a key operator can change (see
figure 108):
Paneltime out
Set timeout
Automatic feed time out