212 Océ TDS600Multifunctional Digital SystemUser Manual
Penpriority Pen parameters canbe defined in two ways:
- In the plot data file
-In the Re mote Configuration File (RCF) or Océ Job Ticket (OJT)
Ifpen priority is set to 'Language', thepen parameters defined in
the plot data file will be used. If pen priority is set to 'Setup', the
penparameters defined in the configuration file or the job ticket re-
ceivedwith the plot will be used.
PS no clip If 'PS no clip' is set to 'On'and the plot defines a Page Size (PS)
valueof WxH (Width and Height), the PS is not taken into account.
In that case the plot may be bigger or smaller than the PS.
Emulation
type
Youcan use the 'Emulation type' option to determine the type of
printeryou want to emulate: HP650Cor HP750C. The default em-
ulation type is HP650C, which is backward compatible with old
machines. Differencesoccur in the default pen palette and the de-
fault number of pens. If HP750C is selected, the default p alette is
a grey levelpalette and compatible with HP7 50C.
Line at-
tributes
Ifthe 'HP defau lt'value is set, th eLin e Attributes instruction is ful-
ly emulated. All types of lines ends/joins allowed by the Line at-
tributesspecifications will be therefore printed according to these
specifications. For backward compatibility reason, the interpreta-
tionof this instruction can be disabled('Océ Round value). In that
case,the lines of the p lot will be processed as rounded and without
join.
Penwidth
scaling
Toenab le or disable the pen width scaling .
If enabled: scaling animage wil lscale the pen width correspond-
ingly.
Kanjifont
set
Tospecify the correct font set for the files which contain Kanji
font.
HPGL-2