HPGL-2

Pen priority Pen parameters can be defined in two ways:

-In the plot data file

-In the Remote Configuration File (RCF) or Océ Job Ticket (OJT)

 

If pen priority is set to 'Language', the pen parameters defined in

 

the plot data file will be used. If pen priority is set to 'Setup', the

 

pen parameters defined in the configuration file or the job ticket re-

 

ceived with the plot will be used.

PS no clip

If 'PS no clip' is set to 'On' and the plot defines a Page Size (PS)

 

value of WxH (Width and Height), the PS is not taken into account.

 

In that case the plot may be bigger or smaller than the PS.

Emulation

You can use the 'Emulation type' option to determine the type of

type

printer you want to emulate: HP650C or HP750C. The default em-

 

ulation type is HP650C, which is backward compatible with old

 

machines. Differences occur in the default pen palette and the de-

 

fault number of pens. If HP750C is selected, the default palette is

 

a grey level palette and compatible with HP750C.

Line at-

If the 'HP default' value is set, the Line Attributes instruction is ful-

tributes

ly emulated. All types of lines ends/joins allowed by the Line at-

 

tributes specifications will be therefore printed according to these

 

specifications. For backward compatibility reason, the interpreta-

 

tion of this instruction can be disabled ('Océ Round value). In that

 

case, the lines of the plot will be processed as rounded and without

 

join.

Pen width

To enable or disable the pen width scaling.

scaling

If enabled: scaling an image will scale the pen width correspond-

 

ingly.

Kanji font

To specify the correct font set for the files which contain Kanji

set

font.

212