Bosch Appliances 3.5 manual 9.6.8Control outputs, 9.6.9Audio Bypass, Basic amplifier connections

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 165
Image 165
9.6.8Control outputs

Praesideo 3.5 Installation and User Instructions 4 Amplifiers

en 165

9.6.8Control outputs

Maximum cable length:

1km Contact type:

Relay contact, single pole, change-over contact (SPDT)

Maximum switching power: Refer to the graph.

Off state (unpowered):

C-NC is closed, C-NO is open

9.6.9Audio Bypass

Connector audio in:

XLR-female with locking

Input signal level:

0 dBV nominal

10 dBV maximum Connector audio out: XLR-male

Output signal level:

Loopthrough of the by-pass audio input

 

2.0

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

(A)

0.5

 

 

 

 

 

 

0.4

 

 

 

 

 

 

Current

0.3

 

 

 

 

 

 

0.2

 

 

 

 

 

 

Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

20

30

40

50

100

200

 

 

Contact Voltage (V)

 

 

figure 9.10: Maximum switching power

9.6.10 Basic amplifier connections

Connector (rear side):

RJ45

Preferred cable:

CAT5, unshielded twisted pairs

Maximum cable length:

3 m

Ground short detection resistance: < 50 ohm

Bosch Security Systems 2011-02

Page 165
Image 165
Bosch Appliances 3.5 9.6.8Control outputs, 9.6.9Audio Bypass, Basic amplifier connections, 10: Maximum switching power