Praesideo 3.5 Installation and User Instructions 4 Amplifiers

en 195

For example, the ID selectors in figure 12.8 show address 2C.

E

2

E

2

C

4

C

4

A

6

A

6

 

8

 

8

S701S700

figure 12.8: ID selectors

Make sure that the maximum number of EOL and Loudspeaker Supervision boards is not exceeded.

PRS-1P500 can have a maximum of 80 boards, of which 16 can be LBB4443/00 EOL boards or LBB4441/00 with line supervision enabled.

PRS-2P250 can have a maximum of 40 boards per channel, of which 16 can be LBB4443/00 EOL boards or LBB4441/00 with line supervision enabled.

PRS-4P125 can have a maximum of 20 boards per channel, of which 16 can be LBB4443/00 EOL boards or LBB4441/00 with line supervision enabled.

Note

The number of EOL supervision boards are limited to 16 per channel as the boards are polled more frequently than the loudspeaker supervision boards to comply to the standards for emergency sound systems.

The multi channel interface can have up to 16 supervision boards connected to each basic amplifier channel of the multi channel interface. The maximum number of boards in total across all channels is 80, of which 64 can be LBB4443/00 EOL boards or LBB4441/00 with line supervision enabled. Do not to exceed the maximum number of supervision boards related to the maximum output power of the amplifier channel; see section 12.6.5.

12.5Technical data supervision control board

12.5.1 Physical characteristics

Dimensions (H x W x D): 60 x 50 x 17 mm Weight:

30g Connection:

20 pole flatband cable and connector

Installation:

Plastic brackets for horizontal or vertical installation are delivered with the amplifier.

12.5.2 Climate conditions

Temperature:

-5 to 55 °C (operating)

-20 to 70 °C (non-operating) Relative humidity:

15 to 90%, non-condensing (operating)

5 to 95%, non-condensing (non-operating)

Air pressure: 600 to 1100 hPa

12.5.3 EMC and Safety

Electromagnetic compatibility:

EN55103-1/FCC-47 part 15B

EN55103-2

EN50121-4

EN50130-4

Electrical safety:

IEC60065 (CB-scheme)

EN60065

Approvals:

CE marking

EN60849, EN54-16 and ISO7240-16

IEC60945

12.5.4 Mean time between failure

MTBF:

50,000 hours at +55 °C

(The MTBF doubles for every 10 °C decrease in

temperature.)

Bosch Security Systems 2011-02