figure 21.6: LBB9081 connection diagram

2011-02 Installation and User Instructions 5 Call Stations

en 244

10kΩ

blue

5

 

 

 

10kΩ

 

 

 

black

6

 

 

 

red

3

 

 

 

white

1

 

 

 

black

 

 

(thick)

2

 

 

figure 21.6: LBB9081 connection diagram

red

3

white

1

black

2

figure 21.7: LBB9082 connection diagram

table 21.6: X301 technical data

Microphone input sensitivity: -50 dBV

Input control range: -7 to 8 dB

S/N:

min. 60 dB at default sensitivity Headroom:

min. 30 dB at default sensitivity Bandwidth:

340 to 14000 Hz

(-3 dB with respect to level at 1 kHz)

With the jumper on X300 the kit can be adapted to the type of microphone.

With the jumper connecting pin 1 and pin 2 of X300, a dynamic microphone can be connected to X301, e.g. LBB9081 and LBB9082.

With the jumper connecting pin 2 and pin 3 of X300, an electret condenser microphone can be connected to X301. In this mode, pin 1 and pin 3 of X301 will have a 12 V phantom power supply.

21.2.4 Control input/outputs (X107)

The remote call station kit provides an external interface for one control input and five control outputs. This external interface consists of a pin header with 14 positions (see the PCB for the pin numbering).

table 21.7: X107 connector details

Pin Signal

1PTT input contact

2GND

3Output 1, out (power indicator)

4 Output 1, in (power indicator)

5 Output 2, out (fault indicator)

6 Output 2, in (fault indicator)

7 Output 3, out (call indicator)

8 Output 3, in (call indicator)

9 Output 4, out (system priority indicator)

10 Output 4, in (system priority indicator)

11 Output 5, out (system emergency indicator)

12Output 5, in (system emergency indicator)

13GND

14GND