Bosch Appliances 26.4Installation, 26.3.5Operation, 5 Status LED indications, 10: Installation

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 274
Image 274
26.3.5Operation

Praesideo 3.5 Installation and User Instructions 6 Installation Accessories

en 274

26.3.5Operation

The two LEDs on the fiber interface provide information about the status of the fiber interface.

table 26.5: Status LED indications

Yellow

Green

Status

(Fault)

(Power)

 

Off

Off

Off; no external power

 

 

available.

On

Off

Stand-by; external power to

 

 

POF switched off.

On

On

Operating; external power to

 

 

POF switched on.

Off

On

Operating; no external power

 

 

available, but powered from the

 

 

POF side.

Off

Blink

Fault, no external power

 

 

available and no protocol

 

 

received.

On

Blink

Fault, external power available,

 

 

but no protocol received.

Note

The PRS-FINNA cannot detect if the correct protocol is received. Therefore, its green LED does not show the fault status of table 26.5.

26.4Installation

The fiber interface can be attached to a wall or any other flat surface using a bracket (see figure 26.10). The distance between the holes in the bracket is 40 mm.

6

figure 26.10: Installation

Mounting of this bracket and the unit on a drywall sheet construction requires screws with a minimum screw length of 22 mm (7/8") and a minimum diameter of

2.5mm (3/32"). Mounting was evaluated for use on a drywall surface only.

Bosch Security Systems 2011-02