Bosch Appliances 3.5 manual C \Program Files\Bosch\Praesideo, 27: PCCstImageDef.xml

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 473
Image 473
C:\Program Files\Bosch\Praesideo

Praesideo 3.5 Installation and User Instructions 11 Optional Software

en 473

table 59.1: Item list of PCCstImages

33A/C

Zone status: occupied by other emergency call (unselected, selected for emergency call)

33F/H

Zone group status: occupied by other emergency call (unselected, selected for emergency call)

 

 

34A-C

Zone status: occupied by other emergency call, no control possible (unselected, selected for

 

business call, selected for emergency call)

34F-H

Zone group status: occupied by other emergency call, no control possible (unselected, selected

 

for business call, selected for emergency call)

35A-C

Zone status: free, no control possible (unselected, selected for business call, selected for

 

emergency call)

 

35F-H

Zone group status: free, no control possible (unselected, selected for business call, selected for

 

emergency call)

 

36B/C

Zone status: running own call (business, emergency)

36G/H

Zone group status: running own call (business, emergency)

37A/B

Zone status: BGM (unselected, selected)

37F/G

Zone group status: BGM (unselected, selected)

38A/B

Zone status: local BGM (unselected, selected)

38F/G

Zone group status: local BGM (unselected, selected)

39A

Zone status: BGM, no control possible

 

39F

Zone group status: BGM, no control possible

40A

Zone status: local BGM, no control possible

40F

Zone group status: local BGM, no control possible

41B

Zone status: occupied by selected BGM channel

41G

Zone group status: occupied by selected BGM channel

42A

Zone status: no status available due to communication error

42F

Zone group status: no status available due to communication error

 

 

 

43A

Zone status: icon overlay for zone fault

 

43F

Zone group status: icon overlay for zone fault

44F-H

Zone group status: partially occupied by other call, some control possible (unselected, selected

 

for business call, selected for emergency call)

45F-H

Zone group status: partially occupied by other call, no control possible (unselected, selected for

 

business call, selected for emergency call)

46G/H

Zone group status: running own partial call (business, emergency)

The file PCCstImageDef.xml, see figure 59.27, which is

 

located in the folders

 

C:\Program Files\Bosch\Praesideo

 

Vx.yy.zzzz\Programs\PCCstConfgurationClient\ and

 

C:\Program Files\Bosch\Praesideo

 

Vx.yy.zzzz\Programs\PCCstClient\ contains information

 

about the actual position and size of the buttons, icons

 

and indicators in the PCCstImages.png file. Making

 

changes to this xml-file allows for changing the size or

 

position of individual items of the PCCstImages.png file

 

because it is used as a reference for the coordinates of

 

the actual items in the png-file. The files

 

PCCstImageDef.xml and PCCstImages.png in the same path

 

belong to each other.

figure 59.27: PCCstImageDef.xml

Bosch Security Systems 2011-02

Page 473
Image 473
Bosch Appliances 3.5 manual C \Program Files\Bosch\Praesideo, Vx.yy.zzzz\Programs\PCCstConfgurationClient\ and