55.10.2 CobraNet Configuration dialog

Praesideo 3.5 Installation and User Instructions 11 Optional Software

en 442

55.10.2 CobraNet Configuration dialog

This dialog shows each transmitter and receiver in the device along with its bundle number assignment and transmission or reception status. A non zero value in the Status column indicates that the transmitter or receiver is receiving or sending a bundle. In addition to transmitter and receiver information, the dialog will also display the IP address currently assigned to the device as well as its conductor status: the Conductor check box will be checked if the device is the conductor for the network.

figure 55.5: CobraNet device configuration dialog

Six actions are supported from the main Configuration dialog:

Press the Configure button with a transmitter (Tx) highlighted to launch the Transmitter Configuration dialog.

Press the Configure button with a receiver (Rx) highlighted to launch the Receiver Configuration dialog.

Press the Report button to launch the single Report Generation dialog.

Press the Advanced button to launch the Advanced dialog.

Press the SNMP button to launch the Generic SNMP R/W dialog. This Button is not displayed by default and must be enabled using the Disco Options applet.

Single click on a Bundle number to edit/change the number.

You may also double click on a Tx or Rx line to invoke the configuration dialog for that transmitter or receiver.

55.10.3 Transmitter Configuration

The Transmitter configuration dialog is launched from the main Configuration dialog by highlighting the line containing the transmitter information and then pressing the Configure button, or by double clicking on the line containing the transmitter information.

figure 55.6: Transmitter configuration dialog

The Transmitter configuration dialog provides access to the most useful configuration variables associated with a transmitter. Please refer to the CobraNet Programmer's Reference Manual for more detailed and up to date information regarding the meaning and usage of these variables. This manual is in the folder \Manuals\CobraNet on the Praesideo DVD.

Bundle

Allows assigning a bundle number to this transmitter.

SubMap

Defines the audio routing channel assigned to a bundle channel. The Clear All button can be pressed to assign a value of 0 (transmit nothing) to all channels in the bundle. The Praesideo CobraNet interface transmitter channels 1..4 correspond to SubMap numbers 1..4.

SubFormat

Normally the txSubFormat value contains information defining the sample size, sample rate and transmission latency. As sample rate and sample latency must be in agreement with the current value of the modeRateControl variable (settable from the

Bosch Security Systems 2011-02