Bosch Appliances 3.5 manual 12.4Addressing, EOL supervision board, 5: Dimensions

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 194
Image 194
figure 12.5: Dimensions

Praesideo 3.5 Installation and User Instructions 4 Amplifiers

en 194

60

40

50

 

10

3.1

 

5

5

 

70

 

 

40

 

 

78

figure 12.5: Dimensions

3Connect the board to the loudspeaker with the flying leads and the faston connectors (see figure 12.6).

Note

Use one of the faston cables inside the loudspeaker and the supplied faston cable to connect the board to the loudspeaker.

X10

X11

Lsp Out _

Lsp Out +

figure 12.6: Loudspeaker supervision connection

12.3.3 EOL supervision board

The procedure for installing an EOL supervision board is similar to the installation of a loudspeaker supervision board (see section 12.3.2). However, the EOL supervision board does not contain faston connectors (see figure 12.7).

X10

Lsp Out _

Lsp Out +

figure 12.7: EOL supervision connection

Note

The board must be connected after the ceramic terminal block with the thermal fuse. In case of a fire, the thermal fuse will act and disconnect the board from the loudspeaker line. The trip point of the thermal fuse that is connected to the ceramic block is lower than the melting point of the solder on the board to prevent short-circuits in the supervision board and the loudspeaker line.

Note

When the loudspeaker does not contain a ceramic block with a thermal fuse, use an LBC1256/00 EVAC Connection Adapter (see chapter 14).

12.4Addressing

All LBB4441/00 Loudspeaker Supervision Boards and LBB4443/00 EOL Supervision Boards must have an address for communication purposes. All LBB4441/00 Loudspeaker Supervision Boards and LBB4443/00 EOL Supervision Boards that are connected to the same amplifier channel must have a different address. Use the S700 and S701 switches to assign a (hexadecimal) address in the range of 00 to 4F to the board. The S700 switch sets the right digit, whereas the S701 switch sets the left digit of the address. Each switch has 16 hexadecimal positions (0 to F).

Bosch Security Systems 2011-02

Page 194
Image 194
Bosch Appliances 3.5 manual 12.4Addressing, EOL supervision board, 5: Dimensions, 6: Loudspeaker supervision connection