47.3.27 Switch trigger

Praesideo 3.5 Installation and User Instructions 9 System Configuration

en 398

47.3.27 Switch trigger

The Switch trigger action is intended for activating Switch output control outputs or Switch output keypad keys (see section 47.3.28). See figure 47.34 for an overview of the Action programming page for a Switch trigger key.

Note

This action can also be assigned to control inputs.

figure 47.34: Switch trigger key

Action type - Sets the action type.

Priority - Sets the priority of the activated output.

Available outputs - Shows the available Switch output control outputs and keypad keys.

Add/Remove buttons - Using the > and < buttons, selected outputs can be added to or removed from Assigned outputs.

Assigned outputs - Shows the Switch output control outputs and keypad keys that have been assigned to the key.

47.3.28 Switch output

The Switch output action is intended for control outputs and call station keypads or call station keypad kits. The key/input itself is not used by this action; only the indicator/output attached to the key is activated. The Switch output action is activated using a Switch trigger action (see section 47.3.27). See figure 47.35 for the Action programming page for a Switch output key.

figure 47.35: Switch output key

47.3.29 Zone active output

The Zone active output action is intended for control outputs and call station keypads or call station keypad kits. The key/input itself is not used by this action; only the indicator/output attached to the key is activated. A Zone active output key can be assigned to a zone (see section 45.2) and becomes active when a call or BGM is sent to the zone. See figure 47.36 for an overview of the Action programming page for a Zone active output key.

figure 47.36: Zone active output key

47.3.30 Volume override output

The Volume override output action is intended for control outputs and call station keypads or call station keypad kits. The key/input itself is not used by this action; only the indicator/output attached to the key is activated. A