Praesideo 3.5 Installation and User Instructions EN54-16: 2008

en 30

Clause / Requirement

Compliance

Signature

6 The quiescent condition

 

 

Any kind of system information may be displayed during the

Praesideo is compliant.

 

quiescent condition. However, no indications shall be given

 

 

which could be confused with indications used in the

 

 

voice alarm condition,

If the Praesideo system enters the voice alarm condition

 

 

 

each call station will show a red system status LED and the

 

 

 

emergency menu will pop up on the display of the network

 

 

 

controller. In the quiescent condition no red indicators are

 

 

 

used at all and the display of the network controller will

 

 

 

never automatically switch to the emergency menu.

 

fault warning condition,

If the Praesideo system enters the fault warning condition

 

 

 

each call station will show a yellow (blinking or on) power/

 

 

 

fault LED and the faults menu will pop up on the display of

 

 

 

the network controller. In the quiescent condition the

 

 

 

power/fault LED of each call station will be green and the

 

 

 

display of the network controller will never automatically

 

 

 

switch to the faults menu.

 

• disablement condition (option with requirements).

The disablement condition is not implemented in

 

 

 

Praesideo.

 