Bosch Appliances 3.5 manual 36.4Upgrade system software, 3: Correct communication

Models: 3.5

1 498
Download 498 pages 15.1 Kb
Page 313
Image 313
figure 36.3: Correct communication

Praesideo 3.5 Installation and User Instructions 8 Software

en 313

Microsoft Windows 2000 [Version 5.00.2195]

(C)Copyright 1985-2000 Microsoft Corp. C:\>ping 192.168.0.15

Pinging 192.168.0.15 with 32 bytes of data:

Reply from 192.168.0.15: bytes = 32 time<10 ms TTL=128

Reply from 192.168.0.15: bytes = 32 time<10 ms TTL=128

Reply from 192.168.0.15: bytes = 32 time<10 ms TTL=128

Reply from 192.168.0.15: bytes = 32 time<10 ms TTL=128

Ping statistics for 192.168.0.15:

Packets: Sent = 4, Received = 4, Loss = 0 (0% loss)

Approximate round trip in milli-seconds:

Minimum = 0 ms, Maximum = 0 ms, Average = 0 ms

figure 36.3: Correct communication

8Go to Start > Programs > Bosch > Praesideo > FT Application to start the Praesideo File Transfer Application. A screen similar to the one in figure 36.4 appears.

figure 36.4: Connecting to the network controller

9Enter the IP address of the network controller in the NCO address field.

10Enter the correct user name in the Username field and the correct password in the Password field.

If no software has been transferred to the network controller before, the default user name is target and the default password is password.

If software has been transferred to the network controller before, the default user name is admin and the default password is admin.

11Click the Connect to NC button to establish a connection with the network controller. A notification appears.

36.4Upgrade system software

A number of the system files that have been installed on the configuration PC (see section 36.2), must be transferred to the network controller. Proceed as follows:

1Click the Upgrade system software button. A screen similar to the one in figure 36.5 appears.

figure 36.5: File transfer screen

2Click the Upgrade now button. A notification is displayed when the file transfer process is finished.

3Switch the network controller off and then on to restart.

Bosch Security Systems 2011-02

Page 313
Image 313